Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116.128
Filtrar
1.
Sensors (Basel) ; 24(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38610488

RESUMO

Near-infrared spectroscopy (NIRS) during repeated limb occlusions is a noninvasive tool for assessing muscle oxidative capacity. However, the method's reliability and validity remain under investigation. This study aimed to determine the reliability of the NIRS-derived mitochondrial power of the musculus vastus lateralis and its correlation with whole-body (cycling) aerobic power (V̇O2 peak). Eleven healthy active men (28 ± 10 y) twice (2 days apart) underwent repeated arterial occlusions to induce changes in muscle oxygen delivery after 15 s of electrical muscle stimulation. The muscle oxygen consumption (mV̇O2) recovery time and rate (k) constants were calculated from the NIRS O2Hb signal. We assessed the reliability (coefficient of variation and intraclass coefficient of correlation [ICC]) and equivalency (t-test) between visits. The results showed high reproducibility for the mV̇O2 recovery time constant (ICC = 0.859) and moderate reproducibility for the k value (ICC = 0.674), with no significant differences between visits (p > 0.05). NIRS-derived k did not correlate with the V̇O2 peak relative to body mass (r = 0.441, p = 0.17) or the absolute V̇O2 peak (r = 0.366, p = 0.26). In conclusion, NIRS provides a reproducible estimate of muscle mitochondrial power, which, however, was not correlated with whole-body aerobic capacity in the current study, suggesting that even if somewhat overlapping, not the same set of factors underpin these distinct indices of aerobic capacity at the different (peripheral and whole-body systemic) levels.


Assuntos
Músculo Quadríceps , Espectroscopia de Luz Próxima ao Infravermelho , Masculino , Humanos , Reprodutibilidade dos Testes , Ciclismo , Estimulação Elétrica
2.
Sensors (Basel) ; 24(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38610589

RESUMO

Functional electrical stimulation (FES) devices are widely employed for clinical treatment, rehabilitation, and sports training. However, existing FES devices are inadequate in terms of wearability and cannot recognize a user's intention to move or muscle fatigue. These issues impede the user's ability to incorporate FES devices into their daily life. In response to these issues, this paper introduces a novel wearable FES system based on customized textile electrodes. The system is driven by surface electromyography (sEMG) movement intention. A parallel structured deep learning model based on a wearable FES device is used, which enables the identification of both the type of motion and muscle fatigue status without being affected by electrical stimulation. Five subjects took part in an experiment to test the proposed system, and the results showed that our method achieved a high level of accuracy for lower limb motion recognition and muscle fatigue status detection. The preliminary results presented here prove the effectiveness of the novel wearable FES system in terms of recognizing lower limb motions and muscle fatigue status.


Assuntos
Fadiga Muscular , Dispositivos Eletrônicos Vestíveis , Humanos , Eletromiografia , Estimulação Elétrica , Extremidade Inferior
3.
Eur Rev Med Pharmacol Sci ; 28(7): 2654-2661, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38639504

RESUMO

OBJECTIVE: This study aimed to explore the effect of flipped venous catheters combined with spinal cord electrical stimulation on functional recovery in patients with sciatic nerve injury. PATIENTS AND METHODS: 160 patients with hip dislocation and sciatic nerve injury were divided into conventional release and flipped catheter + electrical stimulation groups according to the treatment methods (n=80). Motor nerve conduction velocity (MCV) and lower limb motor function were compared. Serum neurotrophic factors brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) were compared. The frequency of complications and quality of life were also compared. RESULTS: The MCV levels of the common peroneal nerve and tibial nerve in the flipped catheter + electrical stimulation group were greater than the conventional lysis group (p<0.05). After treatment, the lower extremity motor score (LMEs) in the flipped catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). The serum levels of BDNF and NGF in the flip catheter + electrical stimulation group were higher than the conventional lysis group (p<0.05). The complication rate in the flipped catheter + electrical stimulation group was lower than in the conventional release group (6.25% vs. 16.25%, p<0.05). The quality-of-life score in the flip catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). CONCLUSIONS: The flipped venous catheter combined with spinal cord electrical stimulation can improve nerve conduction velocity, lower limb motor function, serum BDNF and NGF levels, reduce complications, and help improve the quality of life of sufferers with sciatic nerve injury. Chictr.org.cn ID: ChiCTR2400080984.


Assuntos
Fator Neurotrófico Derivado do Encéfalo , Neuropatia Ciática , Ratos , Animais , Humanos , Fator Neurotrófico Derivado do Encéfalo/metabolismo , Ratos Sprague-Dawley , Fator de Crescimento Neural/metabolismo , Qualidade de Vida , Neuropatia Ciática/metabolismo , Neuropatia Ciática/terapia , Medula Espinal/metabolismo , Nervo Isquiático , Cateteres , Estimulação Elétrica/métodos
4.
Skin Res Technol ; 30(4): e13678, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38616507

RESUMO

BACKGROUND: We developed and tested the safety and efficacy of a cosmetic device to improve dark circles using electrical muscle stimulation of the orbicularis oculi muscle. METHODS: Overall, 18 participants (36 eyes) were studied. The following five items were evaluated before and after the intervention:(1) the Clinical Dark Circle Score using clinical findings and photographs, (2) transcutaneous oxygen partial pressure (TcPO2) on the lower eyelid, (3) thermography, (4) two-dimensional laser blood flowmetry, and (5) spectrophotometry. RESULTS: The mean score at baseline was 2.0 ± 0.90 (mean ± standard deviation), and that at the end of the study was 1.2 ± 1.0 (Wilcoxon signed-rank sum test, p < 0.0001), indicating a significant reduction. The spectrophotometer showed a significant decrease in a* and L* values before and after use (Wilcoxon signed-rank sum test, p < 0.0001). There was also a weak negative correlation between the change in score and the change in blood flow and TcPO2 measured using a laser perfusion device (Spearman's rank correlation coefficient, r = -0.32 and -0.39, respectively). Stratified analysis of the baseline score showed a strong negative correlation between the change in score and the change in spectrophotometric a* in the subjects/group with mild periocular dark circles (Spearman's rank correlation coefficient, r = -0.46). Contrastingly, no correlation was observed for any of the measurements in the subjects/group with severe periocular dark circles. After 1 month, no device-related ophthalmic adverse events were observed in any of the participants. CONCLUSION: Electrical muscle stimulation could improve periocular dark circles, especially in the subjects/group with mild periocular dark circles, and was safe.


Assuntos
Pálpebras , Músculos Faciais , Humanos , Face , Estimulação Elétrica , Eletricidade
5.
J Cardiothorac Surg ; 19(1): 181, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580985

RESUMO

BACKGROUND: A frequent complication of Fontan operations is unilateral diaphragmatic paresis, which leads to hemodynamic deterioration of the Fontan circulation. A potential new therapeutic option is the unilateral diaphragmatic pacemaker. In this study, we investigated the most effective stimulation location for a potential fully implantable system in a porcine model. METHODS: Five pigs (20.8 ± 0.95 kg) underwent implantation of a customized cuff electrode placed around the right phrenic nerve. A bipolar myocardial pacing electrode was sutured adjacent to the motor point and peripherally at the costophrenic angle (peripheral diaphragmatic muscle). The electrodes were stimulated 30 times per minute with a pulse duration of 200 µs and a stimulation time of 300 ms. Current intensity was the only variable changed during the experiment. RESULTS: Effective stimulation occurred at 0.26 ± 0.024 mA at the phrenic nerve and 7 ± 1.22 mA at the motor point, a significant difference in amperage (p = 0.005). Even with a maximum stimulation of 10 mA at the peripheral diaphragm muscle, however, no effective stimulation was observed. CONCLUSION: The phrenic nerve seems to be the best location for direct stimulation by a unilateral thoracic diaphragm pacemaker in terms of the required amperage level in a porcine model.


Assuntos
Nervo Frênico , Paralisia Respiratória , Humanos , Criança , Suínos , Animais , Diafragma , Paralisia Respiratória/etiologia , Paralisia Respiratória/terapia , Eletrodos , Próteses e Implantes , Estimulação Elétrica
6.
Int J Nanomedicine ; 19: 2341-2357, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38469057

RESUMO

Background: The treatment of long-gap peripheral nerve injury (PNI) is still a substantial clinical problem. Graphene-based scaffolds possess extracellular matrix (ECM) characteristic and can conduct electrical signals, therefore have been investigated for repairing PNI. Combined with electrical stimulation (ES), a well performance should be expected. We aimed to determine the effects of reduced graphene oxide fibers (rGOFs) combined with ES on PNI repair in vivo. Methods: rGOFs were prepared by one-step dimensionally confined hydrothermal strategy (DCH). Surface characteristics, chemical compositions, electrical and mechanical properties of the samples were characterized. The biocompatibility of the rGOFs were systematically explored both in vitro and in vivo. Total of 54 Sprague-Dawley (SD) rats were randomized into 6 experimental groups: a silicone conduit (S), S+ES, S+rGOFs-filled conduit (SGC), SGC+ES, nerve autograft, and sham groups for a 10-mm sciatic defect. Functional and histological recovery of the regenerated sciatic nerve at 12 weeks after surgery in each group of SD rats were evaluated. Results: rGOFs exhibited aligned micro- and nano-channels with excellent mechanical and electrical properties. They are biocompatible in vitro and in vivo. All 6 groups exhibited PNI repair outcomes in view of neurological and morphological recovery. The SGC+ES group achieved similar therapeutic effects as nerve autograft group (P > 0.05), significantly outperformed other treatment groups. Immunohistochemical analysis showed that the expression of proteins related to axonal regeneration and angiogenesis were relatively higher in the SGC+ES. Conclusion: The rGOFs had good biocompatibility combined with excellent electrical and mechanical properties. Combined with ES, the rGOFs provided superior motor nerve recovery for a 10-mm nerve gap in a murine acute transection injury model, indicating its excellent repairing ability. That the similar therapeutic effects as autologous nerve transplantation make us believe this method is a promising way to treat peripheral nerve defects, which is expected to guide clinical practice in the future.


Assuntos
Grafite , Traumatismos dos Nervos Periféricos , Ratos , Camundongos , Animais , Ratos Sprague-Dawley , Grafite/farmacologia , Regeneração Nervosa , Nervo Isquiático/lesões , Traumatismos dos Nervos Periféricos/terapia , Traumatismos dos Nervos Periféricos/patologia , Estimulação Elétrica/métodos
7.
Behav Brain Res ; 464: 114946, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38452975

RESUMO

In this study, we aimed to analyze control mechanisms of short-latency afferent inhibition (SAI) during motor output exertion from an agonist or antagonist muscle. The motor task involved index finger abduction (agonist) and adduction (antagonist). In Experiment 1, motor-evoked potentials (MEPs) were recorded from the first dorsal interosseous (FDI) muscle with and without SAI at three output force levels. In Experiment 2, MEPs were recorded with and without SAI at various time points immediately before the muscle output. Experiment 1 showed that inhibition decreased with an increase in muscle output in the agonist muscle but increased in the antagonist muscle. Experiment 2 showed a decreasing trend of inhibition in the agonist muscle immediately before contraction but showed no significant change in the antagonist muscle. MEPs without electrical stimulation during the reaction time increased in both directions of movement as compared to those in the resting state. These results suggest that SAI modulation strongly influences smooth motor output. Analyzing the inhibitory or enhanced mechanisms during the performance of motor output by SAI in patients with motor impairment and comparing them with the mechanisms seen in healthy participants will improve our understanding of the neurophysiological mechanisms relevant to various situations (e.g., rehabilitation and sports).


Assuntos
Córtex Motor , Humanos , Córtex Motor/fisiologia , Inibição Neural/fisiologia , Músculo Esquelético/fisiologia , Mãos , Dedos/fisiologia , Potencial Evocado Motor/fisiologia , Estimulação Magnética Transcraniana/métodos , Eletromiografia , Estimulação Elétrica
8.
J Assoc Res Otolaryngol ; 25(2): 201-213, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38459245

RESUMO

PURPOSE: Attempts to use current-focussing strategies with cochlear implants (CI) to reduce neural spread-of-excitation have met with only mixed success in human studies, in contrast to promising results in animal studies. Although this discrepancy could stem from between-species anatomical and aetiological differences, the masking experiments used in human studies may be insufficiently sensitive to differences in excitation-pattern width. METHODS: We used an interleaved-masking method to measure psychophysical excitation patterns in seven participants with four masker stimulation configurations: monopolar (MP), partial tripolar (pTP), a wider partial tripolar (pTP + 2), and, importantly, a condition (RP + 2) designed to produce a broader excitation pattern than MP. The probe was always in partial-tripolar configuration. RESULTS: We found a significant effect of stimulation configuration on both the amount of on-site masking (mask and probe on same electrode; an indirect indicator of sharpness) and the difference between off-site and on-site masking. Differences were driven solely by RP + 2 producing a broader excitation pattern than the other configurations, whereas monopolar and the two current-focussing configurations did not statistically differ from each other. CONCLUSION: A method that is sensitive enough to reveal a modest broadening in RP + 2 showed no evidence for sharpening with focussed stimulation. We also showed that although voltage recordings from the implant accurately predicted a broadening of the psychophysical excitation patterns with RP + 2, they wrongly predicted a strong sharpening with pTP + 2. We additionally argue, based on our recent research, that the interleaved-masking method can usefully be applied to non-human species and objective measures of CI excitation patterns.


Assuntos
Implante Coclear , Implantes Cocleares , Animais , Humanos , Mascaramento Perceptivo , Estimulação Elétrica
9.
Sci Rep ; 14(1): 7250, 2024 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538655

RESUMO

Animal evolution is driven by random mutations at the genome level. However, it has long been suggested that there exist physical constraints which limit the set of possible outcomes. In craniate evolution, it has been observed that head features, notably in the genus homo, can be ordered in a morphological diagram such that, as the brain expands, the head rocks more forward, face features become less prognathous and the mouth tends to recede. One school of paleontologists suggests that this trend is wired somewhere structurally inside the anatomy, and that random modifications of genes push up or down animal forms along a pre-determined path. No actual experiment has been able to settle the dispute. I present here an experiment of electric stimulation of the head in the chicken embryo which is able to enhance the magnitude of tension forces during development. This experimental intervention causes a correlated brain shrinkage and rotatory movement of the head, congruent with tissue texture, which proves that head dilation and flexure are intimately linked. Numerical modelling explains why the brain curls when it dilates. This gives support to the idea that there exists, in the texture of the vertebrate embryo, a latent dynamic pattern for the observed paleontological trends in craniates towards homo, a concept known as Inside story.


Assuntos
Evolução Biológica , Galinhas , Animais , Humanos , Embrião de Galinha , Vertebrados , Desenvolvimento Embrionário , Estimulação Elétrica
10.
Med Eng Phys ; 125: 104127, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508804

RESUMO

The monitoring of the neuromuscular blockade is critical for patient's safety during and after surgery. The monitoring of neuromuscular blockade often requires the use of Train of Four (TOF) technique. During a TOF test two electrodes are attached to the ulnar nerve, and a series of four electric pulses are applied. The electrical stimulation causes the thumb to twitch, and the amount of twitch varies depending on the amount of neuromuscular blockade in patient's system. Current medical devices used to assist anesthesiologists to perform TOF monitoring often require free hand movement and do not provide accurate or reliable results. The goal of this work is to design, prototype and test a new medical device that provides reliable TOF results when thumb movement is restricted. A medical device that uses a pressurized catheter balloon to detect the response thumb twitch of the TOF test is created. An analytical model, numerical study, and mechanical finger testing were employed to create an optimum design. The design is tested through a pilot human subjects study. No significant correlation is reported with subjects' properties, including hand size.


Assuntos
Bloqueio Neuromuscular , Fármacos Neuromusculares não Despolarizantes , Humanos , Monitoração Neuromuscular/métodos , Nervo Ulnar/fisiologia , Estimulação Elétrica
11.
Georgian Med News ; (346): 63-67, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38501623

RESUMO

The separation of the two rectus abdominis muscles along the linea alba is termed diastasis of recti abdominis muscles (DRAM). DRAM is a common health problem in people that are both pregnant and postpartum. With a 100% frequency at gestational week 35, it is extremely frequent during pregnancy. Control and function of the trunk are greatly influenced by the musculature of the abdomen. The existence, extent, and duration of DRAM have been connected to low back and pelvic discomfort however the relationship is not conclusive. It has been proven to weaken abdominal muscles and impair their functioning in lumbo-pelvic stability. Additionally, DRAM has been linked to pelvic floor dysfunction. The mechanical control and function of the abdomen can be compromised by diastasis recti, which compromises the abdominal muscles. This study examined the impact of abdominal exercises and neuromuscular electrical stimulation on the DRAM in postnatal females who underwent Caesarean section. A total of 208 individuals, aged between 20 and 34, who had recti diastasis measuring more than 2.5 cm, underwent screening. They were split into two groups at random. Group B only received abdominal exercises, whereas Group A received NMES in addition to their activities. For a period of 12 weeks, the intervention was given to both groups three times a week. Changes have been recorded before and after the intervention. The pressure biofeedback unit, measuring tape, and vernier caliper were employed to evaluate the outcome measures of inter-recti distance, abdominal muscle strength, and waist-hip ratio, respectively. In every outcome, both groups had a highly significant (p<0.05) improvement. Furthermore, after 12 weeks, group A had improved in all measures with highly significant (p<0.05) intergroup comparisons. In comparison to MNES alone, NMES can have a more significant effect on reducing DRAM in postpartum women when paired with abdominal Exercise.


Assuntos
Diástase Muscular , Reto do Abdome , Adulto , Feminino , Humanos , Gravidez , Adulto Jovem , Músculos Abdominais , Cesárea , Diástase Muscular/terapia , Estimulação Elétrica , Terapia por Exercício
12.
J Neural Eng ; 21(2)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38518369

RESUMO

Objective. Primarily due to safety concerns, biphasic pulsatile stimulation (PS) is the present standard for electrical excitation of neural tissue with a diverse set of applications. While pulses have been shown to be effective to achieve functional outcomes, they have well-known deficits. Due to recent technical advances, galvanic stimulation (GS), delivery of current for extended periods of time (>1 s), has re-emerged as an alternative to PS.Approach. In this paper, we use a winner-take-all decision-making cortical network model to investigate differences between pulsatile and GS in the context of a perceptual decision-making task.Main results. Based on previous work, we hypothesized that GS would produce more spatiotemporally distributed, network-sensitive neural responses, while PS would produce highly synchronized activation of a limited group of neurons. Our results in-silico support these hypotheses for low-amplitude GS but deviate when galvanic amplitudes are large enough to directly activate or block nearby neurons.Significance. We conclude that with careful parametrization, GS could overcome some limitations of PS to deliver more naturalistic firing patterns in the group of targeted neurons.


Assuntos
Tecido Nervoso , Neurônios , Neurônios/fisiologia , Estimulação Elétrica
13.
J Neural Eng ; 21(2)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38527367

RESUMO

Objective. The incidence of stroke rising, leading to an increased demand for rehabilitation services. Literature has consistently shown that early and intensive rehabilitation is beneficial for stroke patients. Robot-assisted devices have been extensively studied in this context, as they have the potential to increase the frequency of therapy sessions and thereby the intensity. Robot-assisted systems can be combined with electrical stimulation (ES) to further enhance muscle activation and patient compliance. The objective of this study was to review the effectiveness of ES combined with all types of robot-assisted technology for lower extremity rehabilitation in stroke patients.Approach. A thorough search of peer-reviewed articles was conducted. The quality of the included studies was assessed using a modified version of the Downs and Black checklist. Relevant information regarding the interventions, devices, study populations, and more was extracted from the selected articles.Main results. A total of 26 articles were included in the review, with 23 of them scoring at least fair on the methodological quality. The analyzed devices could be categorized into two main groups: cycling combined with ES and robots combined with ES. Overall, all the studies demonstrated improvements in body function and structure, as well as activity level, as per the International Classification of Functioning, Disability, and Health model. Half of the studies in this review showed superiority of training with the combination of robot and ES over robot training alone or over conventional treatment.Significance. The combination of robot-assisted technology with ES is gaining increasing interest in stroke rehabilitation. However, the studies identified in this review present challenges in terms of comparability due to variations in outcome measures and intervention protocols. Future research should focus on actively involving and engaging patients in executing movements and strive for standardization in outcome values and intervention protocols.


Assuntos
Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico , Reabilitação do Acidente Vascular Cerebral/métodos , Extremidade Inferior , Estimulação Elétrica , Extremidade Superior , Recuperação de Função Fisiológica
14.
J Neural Eng ; 21(2)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38502956

RESUMO

Objective.Minimally invasive neuromodulation therapies like the Injectrode, which is composed of a tightly wound polymer-coated Platinum/Iridium microcoil, offer a low-risk approach for administering electrical stimulation to the dorsal root ganglion (DRG). This flexible electrode is aimed to conform to the DRG. The stimulation occurs through a transcutaneous electrical stimulation (TES) patch, which subsequently transmits the stimulation to the Injectrode via a subcutaneous metal collector. However, it is important to note that the effectiveness of stimulation through TES relies on the specific geometrical configurations of the Injectrode-collector-patch system. Hence, there is a need to investigate which design parameters influence the activation of targeted neural structures.Approach.We employed a hybrid computational modeling approach to analyze the impact of Injectrode system design parameters on charge delivery and neural response to stimulation. We constructed multiple finite element method models of DRG stimulation, followed by the implementation of multi-compartment models of DRG neurons. By calculating potential distribution during monopolar stimulation, we simulated neural responses using various parameters based on prior acute experiments. Additionally, we developed a canonical monopolar stimulation and full-scale model of bipolar bilateral L5 DRG stimulation, allowing us to investigate how design parameters like Injectrode size and orientation influenced neural activation thresholds.Main results.Our findings were in accordance with acute experimental measurements and indicate that the minimally invasive Injectrode system predominantly engages large-diameter afferents (Aß-fibers). These activation thresholds were contingent upon the surface area of the Injectrode. As the charge density decreased due to increasing surface area, there was a corresponding expansion in the stimulation amplitude range before triggering any pain-related mechanoreceptor (Aδ-fibers) activity.Significance.The Injectrode demonstrates potential as a viable technology for minimally invasive stimulation of the DRG. Our findings indicate that utilizing a larger surface area Injectrode enhances the therapeutic margin, effectively distinguishing the desired Aßactivation from the undesired Aδ-fiber activation.


Assuntos
Gânglios Espinais , Neurônios , Humanos , Gânglios Espinais/fisiologia , Dor , Estimulação Elétrica , Simulação por Computador
15.
J Neural Eng ; 21(2)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38457841

RESUMO

Objective.Retinal implants use electrical stimulation to elicit perceived flashes of light ('phosphenes'). Single-electrode phosphene shape has been shown to vary systematically with stimulus parameters and the retinal location of the stimulating electrode, due to incidental activation of passing nerve fiber bundles. However, this knowledge has yet to be extended to paired-electrode stimulation.Approach.We retrospectively analyzed 3548 phosphene drawings made by three blind participants implanted with an Argus II Retinal Prosthesis. Phosphene shape (characterized by area, perimeter, major and minor axis length) and number of perceived phosphenes were averaged across trials and correlated with the corresponding single-electrode parameters. In addition, the number of phosphenes was correlated with stimulus amplitude and neuroanatomical parameters: electrode-retina and electrode-fovea distance as well as the electrode-electrode distance to ('between-axon') and along axon bundles ('along-axon'). Statistical analyses were conducted using linear regression and partial correlation analysis.Main results.Simple regression revealed that each paired-electrode shape descriptor could be predicted by the sum of the two corresponding single-electrode shape descriptors (p < .001). Multiple regression revealed that paired-electrode phosphene shape was primarily predicted by stimulus amplitude and electrode-fovea distance (p < .05). Interestingly, the number of elicited phosphenes tended to increase with between-axon distance (p < .05), but not with along-axon distance, in two out of three participants.Significance.The shape of phosphenes elicited by paired-electrode stimulation was well predicted by the shape of their corresponding single-electrode phosphenes, suggesting that two-point perception can be expressed as the linear summation of single-point perception. The impact of the between-axon distance on the perceived number of phosphenes provides further evidence in support of the axon map model for epiretinal stimulation. These findings contribute to the growing literature on phosphene perception and have important implications for the design of future retinal prostheses.


Assuntos
Retina , Próteses Visuais , Humanos , Estudos Retrospectivos , Retina/fisiologia , Fosfenos , Axônios , Estimulação Elétrica , Percepção
16.
J Neural Eng ; 21(2)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38537268

RESUMO

Objective. Intracortical microstimulation (ICMS) can be an effective method for restoring sensory perception in contemporary brain-machine interfaces. However, the mechanisms underlying better control of neuronal responses remain poorly understood, as well as the relationship between neuronal activity and other concomitant phenomena occurring around the stimulation site.Approach. Different microstimulation frequencies were investigatedin vivoon Thy1-GCaMP6s mice using widefield and two-photon imaging to evaluate the evoked excitatory neural responses across multiple spatial scales as well as the induced hemodynamic responses. Specifically, we quantified stimulation-induced neuronal activation and depression in the mouse visual cortex and measured hemodynamic oxyhemoglobin and deoxyhemoglobin signals using mesoscopic-scale widefield imaging.Main results. Our calcium imaging findings revealed a preference for lower-frequency stimulation in driving stronger neuronal activation. A depressive response following the neural activation preferred a slightly higher frequency stimulation compared to the activation. Hemodynamic signals exhibited a comparable spatial spread to neural calcium signals. Oxyhemoglobin concentration around the stimulation site remained elevated during the post-activation (depression) period. Somatic and neuropil calcium responses measured by two-photon microscopy showed similar dependence on stimulation parameters, although the magnitudes measured in soma was greater than in neuropil. Furthermore, higher-frequency stimulation induced a more pronounced activation in soma compared to neuropil, while depression was predominantly induced in soma irrespective of stimulation frequencies.Significance. These results suggest that the mechanism underlying depression differs from activation, requiring ample oxygen supply, and affecting neurons. Our findings provide a novel understanding of evoked excitatory neuronal activity induced by ICMS and offer insights into neuro-devices that utilize both activation and depression phenomena to achieve desired neural responses.


Assuntos
Cálcio , Córtex Visual , Camundongos , Animais , Estimulação Luminosa , Oxiemoglobinas , Neurônios/fisiologia , Estimulação Elétrica/métodos
17.
J Neural Eng ; 21(2)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38547529

RESUMO

Objective.Neuromodulation, particularly electrical stimulation, necessitates high spatial resolution to achieve artificial vision with high acuity. In epiretinal implants, this is hindered by the undesired activation of distal axons. Here, we investigate focal and axonal activation of retinal ganglion cells (RGCs) in epiretinal configuration for different sinusoidal stimulation frequencies.Approach.RGC responses to epiretinal sinusoidal stimulation at frequencies between 40 and 100 Hz were tested inex-vivophotoreceptor degenerated (rd10) isolated retinae. Experiments were conducted using a high-density CMOS-based microelectrode array, which allows to localize RGC cell bodies and axons at high spatial resolution.Main results.We report current and charge density thresholds for focal and distal axon activation at stimulation frequencies of 40, 60, 80, and 100 Hz for an electrode size with an effective area of 0.01 mm2. Activation of distal axons is avoided up to a stimulation amplitude of 0.23µA (corresponding to 17.3µC cm-2) at 40 Hz and up to a stimulation amplitude of 0.28µA (14.8µC cm-2) at 60 Hz. The threshold ratio between focal and axonal activation increases from 1.1 for 100 Hz up to 1.6 for 60 Hz, while at 40 Hz stimulation frequency, almost no axonal responses were detected in the tested intensity range. With the use of synaptic blockers, we demonstrate the underlying direct activation mechanism of the ganglion cells. Finally, using high-resolution electrical imaging and label-free electrophysiological axon tracking, we demonstrate the extent of activation in axon bundles.Significance.Our results can be exploited to define a spatially selective stimulation strategy avoiding axonal activation in future retinal implants, thereby solving one of the major limitations of artificial vision. The results may be extended to other fields of neuroprosthetics to achieve selective focal electrical stimulation.


Assuntos
Retina , Próteses Visuais , Retina/fisiologia , Células Ganglionares da Retina/fisiologia , Microeletrodos , Axônios/fisiologia , Estimulação Elétrica/métodos
18.
Wounds ; 36(2): 39-42, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38479429

RESUMO

BACKGROUND: Gastrocutaneous fistula is a rare complication following Roux-en-Y gastric bypass, a commonly performed bariatric surgery. While most ECFs respond to conservative management, some do not close despite adequate nutritional support, infection source control, and drainage management. As such, the chronicity of these difficult-to-treat wounds can be physically and economically costly to patients. CASE REPORT: A 53-year-old female with a history of Roux-en-Y gastric bypass developed a gastrocutaneous fistula secondary to a perforated gastrojejunal ulcer, requiring immediate surgical intervention. After being discharged from the hospital, 37 days of conservative management and NPWT did not reduce the size of the fistula tract. To help control the patient's chronic abdominal pain and increase the rate of wound healing, the patient underwent treatment with HFES (20 kHz) delivered using a handheld transcutaneous electrical nerve stimulator. This electrotherapy was found to reduce the majority of the patient's pain within the first treatment session. The patient's fistula also began to decrease in size within 1 week of initiating treatment. CONCLUSION: This case report details the successful closure of a gastrocutaneous fistula after administration of HFES 3 times a week over the course of 25 days. The mechanism of action of HFES and its role in the wound healing process are also discussed.


Assuntos
Derivação Gástrica , Fístula Gástrica , Obesidade Mórbida , Feminino , Humanos , Pessoa de Meia-Idade , Fístula Gástrica/etiologia , Fístula Gástrica/cirurgia , Derivação Gástrica/efeitos adversos , Drenagem , Estimulação Elétrica/efeitos adversos , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia
19.
Physiother Res Int ; 29(2): e2079, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38477078

RESUMO

OBJECTIVE: To investigate the effects of unilateral upper limbs' (ULM) neuromuscular electrical stimulation (NMES) superimposed on a voluntary contraction added to a protocol of intradialytic leg cycle ergometer exercise on muscle strength, functional capacity and quality of life of adult patients with chronic kidney disease (CKD). METHODS: This randomized controlled clinical trial will be carried out at a Brazilian University Hospital. The patients will be evaluated and randomly allocated to an intervention group (i.e., unilateral NMES on the upper limb without hemodialysis fistula for 20 min and leg cycle ergometer for 30 min) or a control group (i.e., unilateral NMES-Sham on the upper limb without hemodialysis fistula for 20 min and leg cycle ergometer for 30 min). The patients will be treated for 8 weeks, with three weekly treatment sessions totaling 24 sessions. MEASUREMENTS: ULM muscle strength, functional capacity, quality of life and also the feasibility, safety and patient adherence to the exercise protocol. All physical measurements will be collected by trained researchers before treatment (week 0) and at the end of treatment (week 9), always in the second hemodialysis session of the week. It will be used in an intention-to-treat analysis. RESULTS/CONCLUSIONS: The outcomes of this clinical trial protocol may help to know the possible benefits of unilateral ULM' NMES superimposed on a voluntary contraction added to a protocol of leg cycle ergometer for patients with CKD and to aid clinical decisions about future implementation or not of this technique (NMES) in intradialytic physical training programs.


Assuntos
Terapia por Estimulação Elétrica , Fístula , Insuficiência Renal Crônica , Adulto , Humanos , Qualidade de Vida , Perna (Membro) , Força Muscular/fisiologia , Terapia por Estimulação Elétrica/métodos , Estimulação Elétrica , Extremidade Superior , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
Sci Rep ; 14(1): 5848, 2024 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-38462654

RESUMO

Belt electrode-skeletal muscle electrical stimulation (B-SES) involves the use of belt-shaped electrodes to contract multiple muscle groups simultaneously. Twitch contractions have been demonstrated to protect against denervation-induced muscle atrophy in rats, possibly through mitochondrial biosynthesis. This study examined whether inducing tetanus contractions with B-SES suppresses muscle atrophy and identified the underlying molecular mechanisms. We evaluated the effects of acute (60 Hz, 5 min) and chronic (60 Hz, 5 min, every alternate day for one week) B-SES on the tibialis anterior (TA) and gastrocnemius (GAS) muscles in Sprague-Dawley rats using belt electrodes attached to both ankle joints. After acute stimulation, a significant decrease in the glycogen content was observed in the left and right TA and GAS, suggesting that B-SES causes simultaneous contractions in multiple muscle groups. B-SES enhanced p70S6K phosphorylation, an indicator of the mechanistic target of rapamycin complex 1 activity. During chronic stimulations, rats were divided into control (CONT), denervation-induced atrophy (DEN), and DEN + electrically stimulated with B-SES (DEN + ES) groups. After seven days of treatment, the wet weight (n = 8-11 for each group) and muscle fiber cross-sectional area (CSA, n = 6 for each group) of the TA and GAS muscles were reduced in the DEN and DEN + ES groups compared with that in the CON group. The DEN + ES group showed significantly higher muscle weight and CSA than those in the DEN group. Although RNA-seq and pathway analysis suggested that mitochondrial biogenesis is a critical event in this phenomenon, mitochondrial content showed no difference. In contrast, ribosomal RNA 28S and 18S (n = 6) levels in the DEN + ES group were higher than those in the DEN group, even though RNA-seq showed that the ribosome biogenesis pathway was reduced by electrical stimulation. The mRNA levels of the muscle proteolytic molecules atrogin-1 and MuRF1 were significantly higher in DEN than those in CONT. However, they were more suppressed in DEN + ES than those in DEN. In conclusion, tetanic electrical stimulation of both ankles using belt electrodes effectively reduced denervation-induced atrophy in multiple muscle groups. Furthermore, ribosomal biosynthesis plays a vital role in this phenomenon.


Assuntos
Tétano , Ratos , Animais , Ratos Sprague-Dawley , Músculo Esquelético/metabolismo , Atrofia Muscular/etiologia , Atrofia Muscular/prevenção & controle , Estimulação Elétrica , Denervação , Eletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...